Electrode thickness measurement & electrode coating thickness measurement
Industry pain points and demands
The slurry is uniformly coated on the metal foil and dried to make positive and negative electrode pieces. In order to ensure the uniform coating effect, the thickness of the electrode pieces must be tested to quickly show the uneven coating thickness. Multi-pair deep view intelligent high-precision laser displacement sensor SG5025 is used to measure the thickness of the pole plate synchronously and continuously.
Advantages & characteristics
01
The SG series has a maximum sampling frequency of 590kHz
02
The static repetition accuracy is 0.02μm
03
Under the same configuration, the cost advantage is obvious
Camera Selection
Model number | SG5020/SG5025 | ||
Reference distance (CD) | 20mm | ||
Measuring range | -3mm~3mm | ||
Light source | Light source wavelength | 655nm | |
Laser class | Class 2 | ||
Laser output power | 5mW | ||
Spot diameter (spot size) | Speck of light | Φ 45 microns | |
Wide spot | 45 * 400 microns | ||
Repetition accuracy ① | 0.02 mu m | ||
linearity | ±0.02% of F.S. | ||
Temperature characteristic | 0.01% F.S./℃ | ||
Sampling frequency (Hz) | 1/2/5/10/20/50 KHZ / 88/200/400/590 (optional 10 level) | ||
Input/output | Communication port | One 100Base-TX/1000Base-T Ethernet interface, one RS232 | |
Analog output | 1 analog output, support analog voltage and analog current switching | ||
Encoder input | 1 group difference encoder | ||
IO input | 14, support timing, zero, reset, laser control, formula switching and other functions | ||
IO output | 16 channels, determine the status output | ||
Storage temperature | -20 ~ 70℃ | ||
Operating temperature | 0 ~ 50 ° C | ||
Working humidity | 35% to 85% no condensation | ||
EFT protection | Power port 2kV/5 or 100kHz, signal port 1kV/5 or 100kHz, in accordance with IEC 61000-4-4 standards | ||
ESD protection | Contact discharge is 4kV and air discharge is 8kV, in line with IEC 61000-4-2 standards | ||
Vibration | 10Gs (10-500Hz), compliant with IEC 68-2-6 Fc standard | ||
Impact | 50Gs/3ms per axis, in accordance with IEC 68-2-27 Ea standard | ||
IP level | IP67, in accordance with IEC 60529 standard | ||
Size (mm) | 60*61*41 | ||
Data cable (wiring) model | SCB-GICAM-HA2-3m/5m/10m | ||
Weight (including cables) | 324g |