PACK segment welding guide
Industry pain points and demands
The welding of lithium battery PACK segment includes the welding of positive and negative extremes, collector plate and busbar, etc. In order to ensure the overall welding quality of PACK segment, positioning and guidance must be carried out before welding. The deep view intelligent high precision laser displacement sensor SGI400 is used for ranging before welding, which can accurately position the welding height.
Advantages & characteristics
01
Connect to four-channel EtherCAT communication module, flexible installation topology
02
Built-in data storage function, can store a maximum of 1.2 million data
03
Provide rich communication methods to meet the diverse detection needs
Camera Selection
Model number | SGI400/SGI405 | ||
Reference distance (CD) | 400mm | ||
Measuring range | -100mm~100mm | ||
Light source | Light source wavelength | 655nm | |
Laser class | Class 2 | ||
Laser output power | 5mW | ||
Spot diameter (spot size) | Speck of light | Φ 450 microns | |
Wide spot | 450 * 1300 microns | ||
Repetition accuracy ① | 2 microns | ||
linearity | ±0.05% F.S. | ||
Temperature characteristic | 0.01% F.S./℃ | ||
Sampling frequency (Hz) | 1/2/5/10/20/50/88kHz(7 levels optional) | ||
Input/output | Communication port | One 100Base-TX/1000Base-T Ethernet port, one RS485 port | |
Analog output | 1 analog output, support analog voltage and analog current switching | ||
IO input | 2 way, timing, return to zero function and single-end encoder function multiplexing | ||
IO output | 4, determine the status output | ||
Operating temperature | 0 ~ 50 ℃ | ||
Storage temperature | -20 ~ 70℃ | ||
Working humidity | 35% to 85% no condensation | ||
EFT protection | Power port 2kV/5 or 100kHz, signal port 1kV/5 or 100kHz, in accordance with IEC 61000-4-4 standards | ||
ESD protection | Contact discharge is 4kV and air discharge is 8kV, in line with IEC 61000-4-2 standards | ||
Vibration | 10Gs (10-500Hz), conform to the IEC 2-6 Fc standard | ||
Impact | 50Gs/3ms per axis conforms to the IEC 2-27 Ea standard | ||
IP level | IP67, in accordance with IEC 60529 standard | ||
Size (mm) | 119*85*35 | ||
Data cable (wiring) model | SCB-GICAM-HA1-3m/6m/10m | ||
Weight (including cables) | 380g |